Description
The SLC-457 timer is designed for time counting in range from 0 to 100 hours with resolution of 1 min. Actual result is showed on 4-digit display, and the user can change it's bright in 8 steps range. The device is equipped with 4 buttons for main presets programming. To get high protection level IP 67, the keypad is mounted under transparent waterproof cover. This feature allows to use SLC-457 in hazardous environments. The 24V DC / 100 mA output is designed to supply measuring transducers, and the RS-485 port enables data transmission in production process monitoring systems. Baud rate can be changed from 1200 to 115200 baud.
Specification
Number of inputs |
1
|
Input type |
pulse
|
Input levels |
low: 0...3V; high: 10...30V
|
Output type |
24V DC
|
Measurement unit |
hh.mm. (hour.minutes)
|
Measurement method |
electrical, pulse
|
Power supply |
16...35V AC, 19...50V DC
85..260V AC/DC
|
Display |
LED, 4 x 57 mm, red
|
Communication Interface |
RS-485 / Modbus RTU
|
Transmission parameters |
1200...115200 bit/s, 8N1 / 8N2
|
Operating temperature |
0...+50°C
-20…+50°C
|
Protection class |
IP 67
|
Case material |
ABS
polycarbonate
|
Mounting |
wall
|
Case dimensions |
230 x 140 x 96,5 mm
|
Files
Data sheet | |
Manual EN | |
Brochure EN | |
Declaration of conformity |