Loading

SPP-94

Code: SPP-94
  • flow meter, batcher, totalizer
  • 1 input 0/4-20 mA + 1 programmable function input
  • 0, 2 or 4 REL / OC outputs
  • analogue output: active or passive, power supply output: 24V DC
  • RS-485 / Modbus RTU
  • display of instantaneous and the total flow values
  • batching and counting of doses
  • free configuration software S-Config
Description

The SPP-94 flow counters are designed to work together with flow transducers equipped with analogue input. The purpose of flow counters is to measure the instantaneous flow value and to record the total flow of media like liquids, gases or loose materials. A wide range of total flow indication (up to 16 digits) allows controlling the flow value for a long operation time. Thanks to the built-in batcher function the SPP-94 counters can be used in many industries like: food, pharmaceutical or paint and varnish industry. The REL / OC control outputs can be programmed depending on the instantaneous flow value, batcher or total flow value. Additionally the counter may be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The counter can be configured with the local keyboard or free S-Config software via the RS-485 communication port.

Specification
Number of inputs
1
Input type
current (mA)
Input levels
low: 0...1V; high: 10...30V
Output type
relay I=1A, U=30V DC/250V AC (cosø=1)
Open Collector: I=30 mA, U=30V DC, P=100 mW
0/4...20 mA: active current, operating range 0...24 mA max., load resistance 700 Ω max., resolution 13 bit
4...20 mA: passive current, isolated, operating range 2,8...24 mA max., load resistance 600 Ω@24VDC, resolution 13 bit
0/1...5V, 0/2...10V: active voltage, operating range 0...11V max., load resistance min. 2000 Ω, resolution 13 bit
Measurement method
electrical, pulse
Power supply
16...35V AC, 19...50V DC
85..260V AC/DC
11,4...15V AC/DC
Display
LED, 6 x 13 mm, red
LED, 6 x 13 mm, green
Communication Interface
RS-485 / Modbus RTU
Transmission parameters
1200...115200 bit/s, 8N1 / 8N2
Operating temperature
0...+50°C
-20…+50°C
Protection class
IP 20 (case and connection clips)
IP 65 (front)
optional integrated frame for panel cut-out sealing
Case material
NORYL-GFN2S E1
Mounting
panel
Case dimensions
96 x 48 x 100 mm
Files
Data sheet
Manual EN
Declaration of conformity