Loading

SCT120

Code: SCT120
  • thermocouple temperature sensor
  • temperature range -40 ÷ 800°C depending on thermocouple
  • operating temperature of connection heads max. 150°C
  • for mounting in additional protection tube
  • stainless steel AISI316 (1.4401) insert cover
  • spring-loaded insert ensures an excellent connection with the thermowell
  • possibility of mounting a 4…20 mA or 0…10 V temperature transmitter
  • connection head DANW with local display
Description

The thermocouple SCT120 is used for temperature measurement of liquid and gaseous media. The temperature sensor design (replaceable measuring insert) is suitable for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell.

Application areas:

  • installations of technological processes in all industries,
  • mechanical engineering,
  • heating, air conditioning and ventilation installations.

Specification
Measurement range
-40...+800°C (K)
Measuring element
TC N
TC J
TC K
TC S
TC R
TC B
Accuracy
II class
I class
Connection head
B, IP65, -40...150ºC, aluminum
NA, IP65, -40...150ºC, aluminum
DAN, IP65, -40...150ºC, aluminum
DANW, IP65, -40...150ºC, aluminum
Sheath
heat-resistant steel 1.4401
Files
Data sheet EN