The plastic submersible probe CPA-K-809 is designed for continous level measurement in waste water or in most of aggressive media. Basic element is a capacitiv ceramic sensor.
Basic element of the plastic probe is the flush mounted ceramic sensor, which makes cleaning easier when solid parts of the medium deposit on it. Different cable and seal materials are available in order to achieve maximum media compatibility.
Specification
Measurement range |
0...0,4 mH2O up to 0...100 mH2O
|
Output type |
4...20 mA, 2-wire
0...10V, 3-wire
|
Electrical connection |
cable outlet with PUR cable
cable outlet with FEP cable
cable outlet with TPE-U cable
|
Probe diameter |
Ø45 mm
|
Diaphragm |
ceramics Al2O3 (99.9 %)
|
Power supply |
9…32V DC
12,5…32V DC
|
Accuracy |
±0,35%
±0,25%
±0,5%
|
Medium temperature |
-20...+80°C
|
Protection class |
IP 68
|
Case material |
PVDF
high-temperature polypropylene (PP-HT)
|
Case dimensions |
Ø45 x 126 mm
|
Files
Data sheet | |
Manual |