Description
The process pressure transmitter CCA-Xci measures the pressure of gases, steam, dust and fluids. The special-developed capacitive ceramic sensor for this transmitter has a high overpressure capability and excellent media stability.
Several process connections e.g. thread or flange are available. The transmitter is as a standard equipped with HART®-communication, the customer can choose between a two chamber aluminum die cast case or a stainless field housing.
Specification
Measurement range |
0...60 mbar up to 0...20 bar
|
Output type |
4...20 mA, 2-wire
HART
|
Process connection |
G 1/2
G1 1/2
1/2 NPT
flange
|
Diaphragm |
ceramics Al2O3 (99.9 %)
|
Power supply |
12...28V DC
|
Accuracy |
±0,1%
|
Display |
LCD, 5 x 8 mm
LCD, 8 x 5 mm
|
Transmission protocol |
HART®
|
Operating temperature |
-20...+70°C
-40...+70°C
|
Medium temperature |
-25...+125°C
|
Protection class |
IP 67
|
Case material |
stainless steel
aluminium
|
Files
Data sheet | |
Manual |